Vista V3 Electric Strike
Installation Instructions
1
Product Components
1
Strike Body
2
Keeper Shims
3
4-40 x 1/8” Shim Screws
4
4-40 x 3/16” Shim Screws
4. If using Options 1-4, attach Faceplate to Housing as illustrated
below using the 6-32 x 7/16” at-head screws provided with the
Option Kit.
Note: A second set of mounting holes is provided in the Housing
for additional Forward Horizontal Adjustment.
Strike Installation
Faceplate and Housing Assembly
6-32 x 7/16” Faceplate
screws
Faceplate
Housing
6-32 x 5/16”
Socket Head
Screws
Strike Body
Complete Installation
Red/Green
Black
4104 1A
4114 1 Yes: Spacer #1
4107 3 Yes: Spacer #1
4108 2 Yes: Spacer #1
7104 1A
7114 1 Yes: Spacer #1
7107 3 Yes: Spacer #1
7108 2 Yes: Spacer #1
1. Using the chart below determine which Vista 3 Option Kit is required for your application.
Note: Depending on the product being retrotted, you are choosing both a faceplate, and spacer option.
OPTION KIT SELECTION
Trine
2002WR 2 Spacer #2
For example, when replacing a Trine 2002WR series strike, an Option Kit 2 should
be used, as well as spacer #2. No spacer is needed if “None” is listed under spacer.
Model Vista Option Kit Spacer Used
Model Vista Option Kit Spacer
4
Compatibility Chart & Specications
MINIMUM WIRE GAUGE REQUIREMENTS SOLENOID VOLTAGE
12VDC 24VDC
200 feet or less
200 - 300 feet
300 - 400 feet
18 gauge
16 gauge
14 gauge
18 gauge
18 gauge
16 gauge
ELECTRICAL RATINGS FOR SOLENOID CONTINUOUS DUTY
12VDC
60
.20
24VDC
240 60 240
.10 .20 .10
12-16VAC 24VAC
INTERMITTENT DUTY*
Resistance in Ohms
Amps
Solenoids are rated at +/- 10% indicated value.
*10% max duty cycle (2 min. max on time).
CAUTION! This strike is provided as either a 12 or 24 volt unit. Before connecting any device at the installation site,
verify input voltage using a multimeter. Many power supplies and low voltage transformers operate at higher levels
than listed. Any input voltage exceeding 10% of the solenoid rating may cause severe damage to the unit and will void
the warranty.
ELECTRICAL SPECIFICATIONS
HES, Inc.
Phoenix, AZ
800-626-7590
www.hesinnovations.com
TRINE
2002WR 2 Yes: Spacer #2
2007 1 None
2012 1 Yes: Spacer #2
2678 3 Yes: Spacer #2
ROFU
1509 6 None
1702 1 None
1703 3 None
1704 2 None
1802 1 None
1803 3 None
1804 2 None
Model Vista Option Kit Spacer Used
Yes: Spacer #1
Yes: Spacer #1
5
Option Kit
(sold separately)
2. If you are replacing another manufacturer’s electric strike,
rst determine the manufacturer and model number to be
replaced. Using the chart on page 4, choose the appropriate
Option Kit and spacer to be used with the new install and
proceed to step 3.
3. Attach Electric Strike body to Housing as illustrated
below using the 6-32 x 5/16” socket head screws and hex key
packaged with the Option Kit.
5. Install Electric Strike assembly into frame to test latchbolt
interaction.
6. If additional horizontal adjustment is needed, 1 or 2 keeper
shims can be added as illustrated below. If adding a single shim
use the 4-40 x 1/8” screws, or if adding both shims, the longer
4-40 x 3/16” screws should be used.
7. Remove Electric Strike from frame and connect power.
®
RCI
8. Re-install the electric strike into jamb cutout using the
12-24 at-head screws provided in the Option Kit to complete
installation.
005 5 None
012 1 Yes: Spacer #2
1. If this is a new installation, consult pages 2-3 for the
proper template for your option.
© 2012 HES, Inc.
3603006.001 rev E
7/8"
[22.2]
13/16"
[20.6]
21/32"
[16.7]
Housing With Spacer #1
Housing With Spacer #2
Housing With No Spacer
inches
[mm]
13/16”
15/16”
1-13/16”
Yes: Spacer #1
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Vista V3 Electric Strike

Vista V3 Electric StrikeInstallation Instructions1Product Components1 Strike Body 2 Keeper Shims 3

Page 2

2Cutout Templates3Cutout Templates[mm]Inches[mm]Inches[mm]Inches4-7/8” x 1-1/4” Square Corner Faceplate ANSI Metal Jamb InstallationsOPTION 1

Page 3

2Cutout Templates3Cutout Templates[mm]Inches[mm]Inches[mm]Inches4-7/8” x 1-1/4” Square Corner Faceplate ANSI Metal Jamb InstallationsOPTION 1

Page 4

Vista V3 Electric StrikeInstallation Instructions1Product Components1 Strike Body 2 Keeper Shims 3